Data Loggers, Reference Thermometers
- Logs: 16K
- Range: -100/400°C
- Accuracy: ±0.1°C
- Model: CT376DIG
Home » Products » Reference Thermometers » PRECISION Handheld Pt100 Digital Thermometer
The ACCD750P and ACCD755P Handheld Pt100 Thermometers are High Precision, Metrology Grade, NIST Traceable Instruments. These high accuracy thermometers are used when temperature measurement are critical and/or when online documentation is required.
The 750P and 755P are also used as a NIST Standard to verify and calibrate routinely used instruments.
Optional DE-Graph Windows Software for graphic and tabular documentation.
CATALOG No. | DESCRIPTION |
---|---|
ACCD750P |
Single Probe – Pt100 High Precision Digital Thermometer |
ACCD755P |
Dual Probe – Pt100 High Precision Digital Thermometer |
FEATURES:
SPECIFICATIONS:
Measuring Range |
-200°C to +850°C |
Accuracy Pt100 |
±0.03°C from -50°C to +199.99°C otherwise 0.05 % of reading ±0.05°C from -200°C to 200°C |
Resolution |
0.01°C (-200°C to +200°C) otherwise 0.1°C respectively 0.1 % |
Connectors |
DIN 8-pole |
Display |
2-line LCD |
Data Connector |
USB |
Working Temperature |
0 to +40°C (32 to +104°F) |
Housing |
plastic (ABS) |
Dimensions |
8.0” x 3.5” x 1.5” (L-W-H) |
Weight |
0.6 lbs |
Power supply |
1 x 9v battery |
Batterie life |
appr. 20 hr |
CATALOG No. | DESCRIPTION |
---|---|
ACCD0081PD |
Windows Software Smartgraph for online documentation |
ACCD0046 |
USB Data Cable |
ACCD0007PD |
Service Case for instrument, probe & accessories, Blue Plastic with inserts |
ACC99050005 |
Heat-conductive paste 20g for better heat transmission for measuring the surface |
ACCD10795 |
USB Power Pack |
General Purpose Pt100 Probes, ±0.20°C, 4 Wire platinum – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1001PT |
Immersion w/ handle | 8 sec. | -50 to +350°C | 150 x 3mm |
ACCD1002 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 300 x 3mm |
ACCD1005 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 500 x 3mm |
ACCD1006 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 150 x 4mm |
ACCD1007 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 300 x 4mm |
ACCD1059 |
Surface – w/ handle & buffer-block |
45 sec. | -40 to +300°C | 150 x 6mm |
ACCD1075 |
Surface – Self Adhesive silicone patch |
<3 sec. | -20 to +250°C | 35x13x2mm |
High Precision Pt100 Probes, ±0.03°C (-30 to +200°C) – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1018 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 150 x 3mm |
ACCD1019 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 3mm |
ACCD1023 |
Immersion w/ handle | 5 sec. | -200 to +450°C | 300 x 1.4mm |
ACCD1078 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 6.0mm |
CALL: (973) 300-9100
9am to 5pm est
The ACCD750P and ACCD755P Handheld Pt100 Thermometers are High Precision, Metrology Grade, NIST Traceable Instruments. These high accuracy thermometers are used when temperature measurement are critical and/or when online documentation is required.
The 750P and 755P are also used as a NIST Standard to verify and calibrate routinely used instruments.
Optional DE-Graph Windows Software for graphic and tabular documentation.
CATALOG No. | DESCRIPTION |
---|---|
ACCD750P |
Single Probe – Pt100 High Precision Digital Thermometer |
ACCD755P |
Dual Probe – Pt100 High Precision Digital Thermometer |
FEATURES:
SPECIFICATIONS:
Measuring Range |
-200°C to +850°C |
Accuracy Pt100 |
±0.03°C from -50°C to +199.99°C otherwise 0.05 % of reading ±0.05°C from -200°C to 200°C |
Resolution |
0.01°C (-200°C to +200°C) otherwise 0.1°C respectively 0.1 % |
Connectors |
DIN 8-pole |
Display |
2-line LCD |
Data Connector |
USB |
Working Temperature |
0 to +40°C (32 to +104°F) |
Housing |
plastic (ABS) |
Dimensions |
8.0” x 3.5” x 1.5” (L-W-H) |
Weight |
0.6 lbs |
Power supply |
1 x 9v battery |
Batterie life |
appr. 20 hr |
CATALOG No. | DESCRIPTION |
---|---|
ACCD0081PD |
Windows Software Smartgraph for online documentation |
ACCD0046 |
USB Data Cable |
ACCD0007PD |
Service Case for instrument, probe & accessories, Blue Plastic with inserts |
ACC99050005 |
Heat-conductive paste 20g for better heat transmission for measuring the surface |
ACCD10795 |
USB Power Pack |
General Purpose Pt100 Probes, ±0.20°C, 4 Wire platinum – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1001PT |
Immersion w/ handle | 8 sec. | -50 to +350°C | 150 x 3mm |
ACCD1002 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 300 x 3mm |
ACCD1005 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 500 x 3mm |
ACCD1006 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 150 x 4mm |
ACCD1007 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 300 x 4mm |
ACCD1059 |
Surface – w/ handle & buffer-block |
45 sec. | -40 to +300°C | 150 x 6mm |
ACCD1075 |
Surface – Self Adhesive silicone patch |
<3 sec. | -20 to +250°C | 35x13x2mm |
High Precision Pt100 Probes, ±0.03°C (-30 to +200°C) – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1018 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 150 x 3mm |
ACCD1019 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 3mm |
ACCD1023 |
Immersion w/ handle | 5 sec. | -200 to +450°C | 300 x 1.4mm |
ACCD1078 |