CATALOG NO. | DESCRIPTION |
---|---|
LTSRIL8 |
Single use data logger -80 to 40°C (-112 to 104°F) 8K logs note: LTIUSB (USB Interface Cradle) required for operration (formerly LTIUSB) |
LTTRIL8 |
Multi use data logger -80 to 40°C (-112 to 104°F) 8K logs Note: A USB or WiFi Cradle is required for operation |
LTBRACKET |
Wall Mount Bracket |
LTIHID |
USB HID Interface… no drivers required |
LTI-WiFi |
Wireless WiFi Interface cradle |
LTI-WM-WiFi |
Wireless WiFi Wall Mount cradle for realtime cloud data upload |
FEATURES:
SPECIFICATIONS:
Product Model |
TLSRIL8 – Single use TLTRIL8 – Multi-use: up to 1000hrs @ -80°C (-112°F) |
Sensor Measurement Range |
-80°C to +40°C (-112°F to +104°F). |
Operating Temperature Range |
-80°C to +40°C (-112°F to +104°F). |
Storage Temperature Range |
-20°C to +40°C (-4°F to +104°F). |
Rated Temperature Reading Accuracy |
Better than ±1°C (±1.8°F) for -30°C to +20°C (-22°F to +68°F). Better than ±1.2°C (±2.1°F) for -45°C to -30°C (-49°F to -22°F) and +20°C to +40°C (+68°F to +104°F). Better than ±1.7°C (±3.1°F) for -80°C to -45°C (-112°F to -49°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
Rated TemperatureReading Resolution |
Less than 0.1°C (0.2°F) for -80°C to 0.0°C (-112°F to +32°F), Less than 0.2°C (0.4°F) for 0.0°C to +20°C (+32°F to +68°F), Less than 0.5°C (0.9°F) for +20°C to +40°C (+68°F to +104°F) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Sensor Reaction Time |
Typically less than 5 minutes (T90) in moving air (1m/s). |
Recording Capacity |
8031 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging. |
Sampling Interval |
Configurable from 1 minute to several hours |
Logging Start Options |
Push button start or specific date & time. |
Recording Indication |
Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator. |
Download Time |
Typically less than 5 seconds for full memory (8031 readings), depending on computer or readout device used. |
Environmental |
IP65 (roughly equivalent to NEMA 4). |
Power Source |
3.6V low temperature chemistry Lithium Battery (Fixed). |
Battery Life |
Minimum storage life of 12 months before ‘start’. Single use version rated for a typical trip of 2 weeks duration at dry ice temperatures. |
Real Time Clock |
Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
Size |
86mm (3.39″)H x 54.5mm (2.15″)W x 8.6mm (0.34″)T. |
Weight |
33g (1.17 oz) |
Case Material |
Polycarbonate. |
Not applicable
EL-WIFI-TH and EL-WIFI-21CFR-TH models available
CALL: (973) 300-9100
9am to 5pm est
The LogTag® Dry Ice “Probe-less” Temperature Logger operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F). Intended for use in transit monitoring of articles stored in packaging incorporating dry ice cooling agents.
The LogTag® Dry Ice Temperature Logger is easily configured for recording conditions including delayed start, sampling interval, number of readings and configuration of conditions to activate the ALERT indicator.
CATALOG NO. | DESCRIPTION |
---|---|
LTSRIL8 |
Single use data logger -80 to 40°C (-112 to 104°F) 8K logs note: LTIUSB (USB Interface Cradle) required for operration (formerly LTIUSB) |
LTTRIL8 |
Multi use data logger -80 to 40°C (-112 to 104°F) 8K logs Note: A USB or WiFi Cradle is required for operation |
LTBRACKET |
Wall Mount Bracket |
LTIHID |
USB HID Interface… no drivers required |
LTI-WiFi |
Wireless WiFi Interface cradle |
LTI-WM-WiFi |
Wireless WiFi Wall Mount cradle for realtime cloud data upload |
FEATURES:
SPECIFICATIONS:
Product Model |
TLSRIL8 – Single use TLTRIL8 – Multi-use: up to 1000hrs @ -80°C (-112°F) |
Sensor Measurement Range |
-80°C to +40°C (-112°F to +104°F). |
Operating Temperature Range |
-80°C to +40°C (-112°F to +104°F). |
Storage Temperature Range |
-20°C to +40°C (-4°F to +104°F). |
Rated Temperature Reading Accuracy |
Better than ±1°C (±1.8°F) for -30°C to +20°C (-22°F to +68°F). Better than ±1.2°C (±2.1°F) for -45°C to -30°C (-49°F to -22°F) and +20°C to +40°C (+68°F to +104°F). Better than ±1.7°C (±3.1°F) for -80°C to -45°C (-112°F to -49°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
Rated TemperatureReading Resolution |
Less than 0.1°C (0.2°F) for -80°C to 0.0°C (-112°F to +32°F), Less than 0.2°C (0.4°F) for 0.0°C to +20°C (+32°F to +68°F), Less than 0.5°C (0.9°F) for +20°C to +40°C (+68°F to +104°F) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Sensor Reaction Time |
Typically less than 5 minutes (T90) in moving air (1m/s). |
Recording Capacity |
8031 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging. |
Sampling Interval |
Configurable from 1 minute to several hours |
Logging Start Options |
Push button start or specific date & time. |
Recording Indication |
Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator. |
Download Time |
Typically less than 5 seconds for full memory (8031 readings), depending on computer or readout device used. |
Environmental |
IP65 (roughly equivalent to NEMA 4). |
Power Source |
3.6V low temperature chemistry Lithium Battery (Fixed). |
Battery Life |
Minimum storage life of 12 months before ‘start’. Single use version rated for a typical trip of 2 weeks duration at dry ice temperatures. |
Real Time Clock |
Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
Size |
86mm (3.39″)H x 54.5mm (2.15″)W x 8.6mm (0.34″)T. |
Weight |
33g (1.17 oz) |
Case Material |
Polycarbonate. |
Not applicable