Thermco Products

Thermco Products logo
9am to 5pm EST

How to Change Infrared Thermometer from Celsius to Fahrenheit

Infrared thermometers are innovative devices that have revolutionized temperature measurement. These devices measure the temperature of objects in both Fahrenheit and Celsius units without the need for physical contact. They operate by detecting and measuring the infrared radiation emitted by the surface of the object. This makes infrared thermometers incredibly useful for measuring the temperature of hard-to-reach or potentially dangerous places, such as electrical equipment, engines, pipes, or food.

Understanding Infrared Thermometers

Infrared thermometers usually feature a digital display that shows the temperature reading. This display can present the temperature in either Celsius (°C) or Fahrenheit (°F), depending on the user’s preference or the requirements of the task at hand. The ability to switch between these two units is a standard feature in most models. However, the exact method for switching may vary depending on the specific model and brand of your infrared thermometer. Therefore, it is crucial to read the user manual carefully before using your infrared thermometer. This will ensure you understand all its features and how to use them effectively.

For example, with the ScanTemp 485 Handheld Infrared Thermometer, the following instructions apply:

Changing the Temperature Unit from Celsius to Fahrenheit

To change the temperature unit from Celsius to Fahrenheit on the TFA ScanTemp 485 thermometer, follow these steps:

  1. Locate the battery compartment on the thermometer.
  2. Open the battery compartment and look for a slide switch labeled “°C/°F” inside.
  3. Slide the switch to the desired temperature unit. For Fahrenheit, slide the switch to the “°F” position.
  4. Close the battery compartment securely.
  5. The thermometer will now display temperature readings in the selected unit (Fahrenheit).

Please note that the specific location and design of the switch may vary slightly depending on the model of the thermometer. Refer to the user manual for detailed instructions and illustrations specific to the TFA ScanTemp 485 thermometer.

If you are unable to locate the switch or encounter any difficulties, it is recommended to consult the user manual or contact customer support for further assistance.

Getting Help

If you encounter any questions or problems with your infrared thermometer, please contact the customer service of your product’s manufacturer. They can provide expert advice and solutions. You can also visit their website for more information and support. Many manufacturers offer detailed guides, FAQs, and troubleshooting tips online.

Thermometer Calibration: Different Types and Methods

Thermometers can lose accuracy over time due to various factors such as aging, mechanical shock, environmental changes, and human error. Therefore, it is essential to calibrate thermometers regularly to ensure their reliability and accuracy. The U.S. Food and Drug Administration (FDA) requires that all inspection, measuring, and test equipment, including thermometers, be routinely calibrated, inspected, checked, and maintained. The FDA also mandates that calibration standards used for inspection, measuring, and test equipment be traceable to national or international standards.

About Thermometer Calibration

Thermometer Calibration is the process of comparing a thermometer’s readings with a known reference standard and adjusting the thermometer if necessary. There are different types of thermometers that require different methods of calibration. In this blog post, we will discuss some of the common types of thermometer calibration and their advantages and disadvantages.

There are two methods widely used for calibrating thermometers: 

  1. Fixed points calibration: A thermometer is calibrated by taking readings at specific temperature reference points, such as freezing or melting points, triple points, or vapor pressure points of pure substances. This is done by placing the thermometer in a fixed point cell that maintains the desired temperature. The fixed points method is the most precise calibration technique, but it’s complex and costly, so it’s not commonly used by calibration laboratories. It’s generally reserved for the highest quality calibrations.
  2. Comparison to standard thermometers: The comparison method is the most popular calibration technique, which involves comparing the thermometer under test with a higher accuracy standard thermometer. This comparison typically occurs in a liquid bath or dry block calibrator. The parameters to consider include immersion depth and the homogeneity of the liquid or air where the thermometer is placed. Immersion depth depends on the thermometer’s construction and temperature differences, while better homogeneity is achieved in liquid baths but can be improved in dry block calibrators with an equalizing block.

Temperature Calibration

Temperature NIST calibration offers calibration of various types of thermometers using high-quality equipment and standards. Accurate temperature calibration can provide traceable certificates that document the calibration results and comply with international standards and regulations.

Some of the benefits of temperature calibration are:

  • Ensures the accuracy and reliability of thermometers across a wide range of temperatures and applications.
  • Reduces the risk of errors and failures that can affect product quality, safety, and performance.
  • Saves time and resources by outsourcing the calibration process to experts who have the necessary skills, equipment, and experience.

Digital Calibration

Digital NIST calibration is a method of calibrating digital thermometers using a device called a digital thermometer calibrator, an instrument that generates precise and stable temperatures that can be used as reference points for digital thermometers. This type of calibration can be performed by following these steps:

  • Connect the digital thermometer to the digital thermometer calibrator using a suitable probe or adapter.
  • Set the digital thermometer calibrator to the desired temperature point and wait for it to stabilize.
  • Compare the reading on the digital thermometer with the reading on the digital thermometer calibrator and note any difference or error.
  • Adjust the digital thermometer if necessary, using its calibration function or software.

Some of the benefits of digital calibration are:

  • Easy and convenient to perform as it does not require any additional equipment or standards.
  • Fast and accurate as it uses precise and stable temperatures generated by the digital thermometer calibrator.
  • Versatile and flexible as it can calibrate different types of digital thermometers with various ranges and resolutions.

Humidity Calibration

Humidity NIST calibration is a method of calibrating hygrometers, which are devices that measure humidity or moisture content in air or other gases. This type of calibration can be performed using two main techniques: relative humidity calibration and dew point calibration.

Relative Humidity Calibration

Relative humidity calibration is a technique that uses a device called a humidity chamber, which is a sealed enclosure that maintains a constant temperature and humidity level. This type of calibration can be performed by following these steps:

  • Place the hygrometer inside the humidity chamber and close it securely.
  • Set the humidity chamber to the desired humidity level and wait for it to stabilize.
  • Compare the reading on the hygrometer with the reading on the humidity chamber and note any difference or error.
  • Adjust the hygrometer if necessary using its calibration function or software.

Dew Point Calibration

Dew point calibration is a technique that uses a device called a dew point generator, which is an instrument that produces a stream of gas with a known dew point temperature. This type of calibration can be performed by following these steps:

  • Connect the hygrometer to the dew point generator using a suitable tubing or adapter.
  • Set the dew point generator to the desired dew point temperature and wait for it to stabilize.
  • Compare the reading on the hygrometer with the reading on the dew point generator and note any difference or error.
  • Adjust the hygrometer if necessary using its calibration function or software.

Some of the benefits of humidity calibration are:

  • It ensures the accuracy and reliability of hygrometers across a wide range of humidity levels and applications.
  • It reduces the risk of errors and failures that can affect product quality, safety, and performance.
  • It saves time and resources by outsourcing the calibration process to experts who have the necessary skills, equipment, and experience.

Infrared Calibration

Infrared NIST calibration is a method of calibrating infrared thermometers, which are devices that measure temperature by detecting the infrared radiation emitted by an object. This type of calibration can be performed using a device called an infrared calibrator, an instrument that emits a known amount of infrared radiation that can be used as a reference point for infrared thermometers. Infrared calibration can be performed by following these steps:

  • Align the infrared thermometer with the infrared calibrator using a suitable mount or stand.
  • Set the infrared calibrator to the desired temperature point and wait for it to stabilize.
  • Compare the reading on the infrared thermometer with the reading on the infrared calibrator and note any difference or error.
  • Adjust the infrared thermometer if necessary using its calibration function or software.

Some of the benefits of infrared calibration are:

  • It is easy and convenient to perform as it does not require any contact or immersion of the thermometer in a medium.
  • It is fast and accurate as it uses precise and stable temperatures generated by the infrared calibrator.
  • It is versatile and flexible as it can calibrate different types of infrared thermometers with various ranges and resolutions.

Liquid-in-Glass Calibration

Liquid-in-glass NIST calibration is a method of calibrating liquid-in-glass thermometers, which are devices that measure temperature by observing the expansion or contraction of a liquid in a glass tube. This type of calibration is performed using a liquid-in-glass calibrator. This instrument provides a controlled environment for immersing and comparing liquid-in-glass thermometers. Liquid-in-glass calibration is done by following these steps:

  • Place the liquid-in-glass thermometer inside the liquid-in-glass calibrator and secure it firmly.
  • Set the liquid-in-glass calibrator to the desired temperature point and wait for it to stabilize.
  • Compare the reading on the liquid-in-glass thermometer with the reading on a reference thermometer and note any difference or error.
  • Adjust the liquid-in-glass thermometer if necessary using its calibration function or software.

Some of the benefits of liquid-in-glass calibration are:

  • It is simple and reliable as it uses a direct comparison of two thermometers in the same medium.
  • It is inexpensive and portable as it does not require any sophisticated equipment or standards.
  • It is compatible and universal as it can calibrate most types of liquid-in-glass thermometers with various ranges and resolutions.

Conclusion

Thermometer calibration is an important process that ensures the accuracy and reliability of thermometers in various applications. There are different types of thermometers that require different methods of calibration. Each method has its own advantages and disadvantages. Some of the common types of thermometer calibration are temperature calibration service, digital calibration, humidity calibration, infrared calibration, and liquid-in-glass calibration. By understanding these types and methods, you can select the best option for your needs and expectations.

NIST Traceable Standards: What is NIST Traceability?

In the world of temperature measurement, accuracy and reliability are paramount. This is especially true for industries such as healthcare, food processing, and manufacturing, where even the slightest deviation from the standard can have significant consequences. Enter the National Institute of Standards and Technology (NIST), a non-regulatory agency of the United States Department of Commerce. NIST provides a crucial service in ensuring the accuracy of temperature measurements by establishing and maintaining standards for thermometers. This is known as NIST Traceable standard or NIST Traceability.

What is NIST Traceability?

NIST traceability refers to the unbroken chain of comparisons that lead to a specific and defined NIST Standard Reference Material (SRM). It is a crucial aspect of measurement and calibration; when a device is NIST traceable, it provides confidence in the accuracy of measurements and ensures that they are consistent with the International System of Units (SI). NIST traceability is achieved through a documented chain of comparisons with defined uncertainties.

The Importance of NIST Traceability

  1. Accuracy and Reliability: NIST traceability ensures that the thermometers used in various industries are accurate and reliable. This is important for maintaining the quality of products and services as well as ensuring the safety of consumers.
  2. Consistency and Interoperability: NIST traceability helps to ensure that measurements are consistent across different applications; NIST traceability also promotes interoperability among different organizations, industries, and countries. When measurements are traceable to a common standard, it facilitates data exchange and collaboration on a global scale. This is essential for maintaining the integrity of research and development as well as ensuring that products and services meet the required standards.
  3. Compliance: Many industries are required to adhere to strict standards and regulations when it comes to temperature measurement. NIST traceability helps to ensure that these standards are met. It also helps ensure that the thermometers used in these industries are in compliance with the relevant regulations.
  4. Risk Mitigation: Using NIST traceable measurements helps organizations mitigate the risk of errors and uncertainties in their processes. It enhances confidence in measurement results, reducing the likelihood of costly mistakes.
  5. Cost savings: By ensuring the accuracy and reliability of temperature measurements, NIST traceability can help reduce costs associated with product recalls, waste, and rework. This is especially important for industries where even a small deviation from the standard can have significant financial consequences.
  6. Innovation: NIST traceability also fuels innovation by providing a solid foundation for research and development. Scientists and engineers can trust the accuracy of their measurements, enabling them to push the boundaries of knowledge and technology.

NIST Traceable Thermometer Standards

NIST has established a number of standards for NIST traceable thermometers, including the International Temperature Scale of 1990 (ITS-90). This standard defines the temperature scale and provides a means for calibrating thermometers. The organization also maintains a database of certified reference materials (CRMs) that can be used to calibrate thermometers, including NIST traceable glass thermometers, and ensure their accuracy.

In addition to the ITS-90, the NIST has also established standards for specific types of thermometers, such as infrared thermometers and thermocouples. These standards provide guidelines for the design, calibration, and use of these thermometers, ensuring that they are accurate and reliable.

NIST Traceable Calibration

To achieve NIST traceability, the following key components are necessary:

  1. A Defined Standard: NIST maintains a comprehensive set of measurement standards for various physical quantities. These standards are meticulously calibrated and periodically updated to ensure their accuracy.
  2. Calibration Laboratories: Organizations or calibration labs that perform measurements and calibrations must have their instruments calibrated against the NIST standards. This step creates a direct connection to NIST’s reference standards.
  3. Chain of Comparisons: The calibration lab’s measurements should be traceable to NIST through a documented chain of comparisons. Each step in the chain must be traceable to a higher-level standard until it reaches a NIST standard.
  4. Documentation: Every calibration and measurement process should be thoroughly documented. This includes the instruments used, the methods applied, and the results obtained. This documentation provides transparency and ensures the traceability of the measurement.

Conclusion

NIST traceability and its standards for thermometers play a crucial role in ensuring the accuracy and reliability of temperature measurements.  By following these guidelines, businesses can guarantee the security of their customers, uphold the caliber of their goods and services, and abide by applicable laws. Industries that depend on precise and trustworthy temperature readings can benefit greatly from the NIST’s ongoing efforts to improve temperature measurement accuracy and uphold the integrity of its standards.