Data Loggers, Vaccine Temperature Monitors
- Logs: 24M
- Range: -40/50°C
- Accuracy: ± 0.5°C
- Model: ACCSL2021
Home » Products » Data Loggers » LogTag® TRED30-16R Data Logger
The LogTag® TRED30-16R is a CDC / VFC compliant ISO/IEC 17025 NIST traceable temperature data logger used to monitor & record the temperatures of vaccines in refrigerators or freezers. The LogTag TRED30-16R measures and stores up to 15.9K readings over a temperature range of -40° to +99°C (-40° to +210°F) via external bottle probe. The display is designed to show “At A Glance” if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status. The alarm is trigged if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to an X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option. Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder’s display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.
Note: The TRED30-16R supersedes the existing TRED30 model.
Summary of TRED30-16R updates.
• Built-in audible alarm.
• New, easy to read LCD display with 30 day summary in calendar format.
• Up to 15.9K recordings – Enough memory for 66 days at 6 minute logging.
• Auto-pause function – unplugging the external probe automatically suspends alarm & statistics processing.
Documents
TRED30-16R Quick Start Guide
Product User Guide
Software
LogTag Analyzer User Guide… Software Revision: 3.0 Document Revision: 2 Published: 12 January 2018
LogTag Analyzer 3.2.2
LogTag download page for additional software and drivers
CATALOG NO. | DESCRIPTION |
---|---|
LTTRED3016R |
Temperature Data Logger – 15.9K logs w/Probe and Vial Note: A USB or WiFi Cradle is required for operation |
LTTRED3016RUSB |
VFC Approved Temperature Data Logger, w/Probe, Vial and USB Interface Cradle |
LTISOLOGTEMP |
ISO17025/IEC Accredited Temperature Calibration |
LTBRACKET |
Wall Mount Bracket |
LTI-HID |
USB HID Interface… no drivers required |
LTI-WiFi |
Wireless WiFi Interface cradle |
LTI-WM-WiFi |
Wireless WiFi Wall Mount cradle for realtime cloud data upload |
LTST100B-15 |
Replacement Probe and Vial for LTTRED3016R |
FEATURES:
SPECIFICATIONS:
External Temperature Sensor Measurement Range |
-40°C ~ +99°C (-40°F ~ +210°F) |
Operating Temperature Range |
-30°C ~ +60°C (-22°F ~ +140°F) |
Storage Temperature Range |
-10°C ~ +40°C (-14°F ~ +104°F) |
Rated Temperature Reading Accuracy |
Better than ±0.5°C ( ±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F) Better than ±0.8°C ( ±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F) Better than ±0.8°C ( ±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F) Better than ±1.2°C ( ±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F) Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart above. Accuracy figures can be improved by recalibration. |
Rated Temperature Reading Resolution |
0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F) 0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F) 0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F) 0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F) Please see the Rated Native Resolution chart above. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Recording Capacity |
15.9K temperature readings. 66 days @ 6min logging. Day summary statistics memory (for display on LCD): up to 30 days of Max/Min/duration and alarm trigger statistics. |
Sampling Frequency |
Configurable from 30 seconds to hourly. |
Sensor Reaction Time |
Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T,ST100H & ST100S types. |
Logging Start Options |
Push button start or specific date & time. Optional start delay of up to 18hours. |
Recording Indication |
State indicator REC |
Download Time |
Typically less than 10 seconds for full memory (15.9K readings), depending on computer or readout device used. |
Environmental |
IP61 (when vertically mounted or hung). |
Power Source |
3V CR2032 (LiMnO2) coin cell battery, user replaceable |
Battery Life |
Typically 1 year of operation. NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. Download data monthly. NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
Size |
93mm(H) x 54.5mm(W) x 8.6mm(T) |
Weight |
41grams without External Probe |
Case Material |
Polycarbonate |
Standard External Probe Cable Lengths |
Standard: 1.5m (4’11”). Extended: 3 m (9’10”) (recommended maximum). |
Remote External Probe Type |
PTFE (FDA food contact rated) coaxial. |
Not applicable
CALL: (973) 300-9100
9am to 5pm est
The LogTag® TRED30-16R is a CDC / VFC compliant ISO/IEC 17025 NIST traceable temperature data logger used to monitor & record the temperatures of vaccines in refrigerators or freezers. The LogTag TRED30-16R measures and stores up to 15.9K readings over a temperature range of -40° to +99°C (-40° to +210°F) via external bottle probe. The display is designed to show “At A Glance” if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status. The alarm is trigged if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to an X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option. Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder’s display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.
Note: The TRED30-16R supersedes the existing TRED30 model.
Summary of TRED30-16R updates.
• Built-in audible alarm.
• New, easy to read LCD display with 30 day summary in calendar format.
• Up to 15.9K recordings – Enough memory for 66 days at 6 minute logging.
• Auto-pause function – unplugging the external probe automatically suspends alarm & statistics processing.
Documents
TRED30-16R Quick Start Guide
Product User Guide
Software
LogTag Analyzer User Guide… Software Revision: 3.0 Document Revision: 2 Published: 12 January 2018
LogTag Analyzer 3.2.2
LogTag download page for additional software and drivers
CATALOG NO. | DESCRIPTION |
---|---|
LTTRED3016R |
Temperature Data Logger – 15.9K logs w/Probe and Vial Note: A USB or WiFi Cradle is required for operation |
LTTRED3016RUSB |
VFC Approved Temperature Data Logger, w/Probe, Vial and USB Interface Cradle |
LTISOLOGTEMP |
ISO17025/IEC Accredited Temperature Calibration |
LTBRACKET |
Wall Mount Bracket |
LTI-HID |
USB HID Interface… no drivers required |
LTI-WiFi |
Wireless WiFi Interface cradle |
LTI-WM-WiFi |
Wireless WiFi Wall Mount cradle for realtime cloud data upload |
LTST100B-15 |
Replacement Probe and Vial for LTTRED3016R |
FEATURES:
SPECIFICATIONS:
External Temperature Sensor Measurement Range |
-40°C ~ +99°C (-40°F ~ +210°F) |
Operating Temperature Range |
-30°C ~ +60°C (-22°F ~ +140°F) |
Storage Temperature Range |
-10°C ~ +40°C (-14°F ~ +104°F) |
Rated Temperature Reading Accuracy |
Better than ±0.5°C ( ±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F) Better than ±0.8°C ( ±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F) Better than ±0.8°C ( ±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F) Better than ±1.2°C ( ±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F) Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart above. Accuracy figures can be improved by recalibration. |
Rated Temperature Reading Resolution |
0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F) 0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F) 0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F) 0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F) Please see the Rated Native Resolution chart above. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Recording Capacity |
15.9K temperature readings. 66 days @ 6min logging. Day summary statistics memory (for display on LCD): up to 30 days of Max/Min/duration and alarm trigger statistics. |
Sampling Frequency |
Configurable from 30 seconds to hourly. |
Sensor Reaction Time |
Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T,ST100H & ST100S types. |
Logging Start Options |
Push button start or specific date & time. Optional start delay of up to 18hours. |
Recording Indication |
State indicator REC |
Download Time |
Typically less than 10 seconds for full memory (15.9K readings), depending on computer or readout device used. |
Environmental |
IP61 (when vertically mounted or hung). |
Power Source |
3V CR2032 (LiMnO2) coin cell battery, user replaceable |
Battery Life |
Typically 1 year of operation. NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. Download data monthly. NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. |
Size |
93mm(H) x 54.5mm(W) x 8.6mm(T) |
Weight |
41grams without External Probe |
Case Material |
Polycarbonate |
Standard External Probe Cable Lengths |
Standard: 1.5m (4’11”). Extended: 3 m (9’10”) (recommended maximum). |
Remote External Probe Type |
PTFE (FDA food contact rated) coaxial. |
Not applicable