Vaccine Temperature Monitors
- Alarm: Yes
- Cloud functionality via EasyLog Cloud Apps for Android and iOS
Home » Products » Vaccine Temperature Monitors » Fridge-tag® Ultra Low Data Logger
The Fridge-tag Ultra low is the intelligent temperature logger for the continuous monitoring of sensitive vaccines and pharmaceuticals stored at ultra low temperatures up to – 90°C.
If an alarm limit is exceeded, an alarm will be triggered on the display and is audible as an audio signal. A quick decision and immediate action is thus possible.
With the built-in USB connection, a secure PDF/A report with all relevant temperature data presented in a clear and easy understandable overview with temperature graph can be generated.
CATALOG NO. | DESCRIPTION |
---|---|
BERFT2ULF |
Ultra Low Vaccine Temp Data Logger –90 to 30°C (–130 to 86°F), 2/yr NIST Traceable Certificate, |
FEATURES:
SPECIFICATIONS:
DESCRIPTION |
Electronic ultra low temperature logger with USB and external Sensor Fridge-tag device must be mounted outside of the Freezer with external sensor placed inside |
MANUFACTURER’S REF |
Fridge-tag Ultra Low |
TYPICAL APPLICATION AREA |
Monitoring of Ultra Low Temperature Freezer down to -90°C |
EXTERNAL DIMENSIONS (L X W X H) |
128 x 75 x 19 mm, Display 95 x 27 mm |
WEIGHT |
112 g |
STORAGE CONDITION (INACTIVE) |
0 °C to +30 °C / +32 °F to +86 °F |
ONLY WITH EXTERNAL SENSOR PLACED INSIDE THE FREEZER (Fridge-tag device must be mounted outside of the Freezer) |
|
OPERATING TEMPERATURE |
–90 to 0°C / –130 to +32°F |
ALARM TEMPERATURE RANGE |
–80°C to -5°C in 0.1°C increments –112°F to +23°F |
ACCURACY OF TEMPERATURE MEASUREMENT |
+/- 1.5°C from –90°C to –30°C +/- 3.2°F from –130°F to –22°F +/- 0.5°C from –30°C to 0°C +/- 0.9°F from –22°F to +32°F |
ALARM LIMITS 2 |
individually programmable alarm limits (1 upper and 1 lower alarm limit) |
ALARM TRIGGER TIME |
1 minute to 23 h 59 min |
ALARM INDICATION |
visual, optional audible (buzzer) |
LOGGING INTERVAL |
5 min (standard) |
MEASUREMENT ACCURACY OF THE TIME |
+/- 30 minutes / year |
CALIBRATION |
Every sensor is factory calibrated according NIST/ILAC standard traceable. Calibration certificate on request |
MEMORY SPACE 30 |
30 day overview on display; PDF report length factory settable: 28, 56, 84 or 112 day overview |
BATTERY |
Lithium battery – complies with IATA DGR Packaging Instruction 970-Section II |
PROTECTION CLASS |
IP64 (external sensor not plugged in) |
2D CODE ON LABEL |
2D data matrix |
OPERATING LIFETIME AND SHELF LIFE |
Up to 3 1/2 years (1/2 year storage / 3 years useful life). The battery status indicator on the display provides information on the remaining lifetime. |
WARRANTY |
2 years from date of delivery (see general Berlinger Terms & Conditions) |
MANIPULATION |
Fridge-tag Ultra Low cannot be manipulated, reset or turned off without destroying it |
FORMAT OF THE ORIGINAL DOCUMENT |
PDF / ASCII (it can also be imported by many ERP or data management systems) |
SOFTWARE FOR VERIFYINGPDF AND ASCII FILE |
www.berlinger.com/verifier JAVA™ / The software verifies the digital signature of the ASCII and PDF files. |
STANDARDS |
CE, EMC, ROHS compliant, REACH |
Subject to change. Please note that all information in this document is correct at the time of publication. Due to our policy of continuous product development, we reserve the right to change this information without prior notice. |
Not applicable
EL-WIFI-TH and EL-WIFI-21CFR-TH models available
CALL: (973) 300-9100
9am to 5pm est
The Fridge-tag Ultra low is the intelligent temperature logger for the continuous monitoring of sensitive vaccines and pharmaceuticals stored at ultra low temperatures up to – 90°C.
If an alarm limit is exceeded, an alarm will be triggered on the display and is audible as an audio signal. A quick decision and immediate action is thus possible.
With the built-in USB connection, a secure PDF/A report with all relevant temperature data presented in a clear and easy understandable overview with temperature graph can be generated.
CATALOG NO. | DESCRIPTION |
---|---|
BERFT2ULF |
Ultra Low Vaccine Temp Data Logger –90 to 30°C (–130 to 86°F), 2/yr NIST Traceable Certificate, |
FEATURES:
SPECIFICATIONS:
DESCRIPTION |
Electronic ultra low temperature logger with USB and external Sensor Fridge-tag device must be mounted outside of the Freezer with external sensor placed inside |
MANUFACTURER’S REF |
Fridge-tag Ultra Low |
TYPICAL APPLICATION AREA |
Monitoring of Ultra Low Temperature Freezer down to -90°C |
EXTERNAL DIMENSIONS (L X W X H) |
128 x 75 x 19 mm, Display 95 x 27 mm |
WEIGHT |
112 g |
STORAGE CONDITION (INACTIVE) |
0 °C to +30 °C / +32 °F to +86 °F |
ONLY WITH EXTERNAL SENSOR PLACED INSIDE THE FREEZER (Fridge-tag device must be mounted outside of the Freezer) |
|
OPERATING TEMPERATURE |
–90 to 0°C / –130 to +32°F |
ALARM TEMPERATURE RANGE |
–80°C to -5°C in 0.1°C increments –112°F to +23°F |
ACCURACY OF TEMPERATURE MEASUREMENT |
+/- 1.5°C from –90°C to –30°C +/- 3.2°F from –130°F to –22°F +/- 0.5°C from –30°C to 0°C +/- 0.9°F from –22°F to +32°F |
ALARM LIMITS 2 |
individually programmable alarm limits (1 upper and 1 lower alarm limit) |
ALARM TRIGGER TIME |
1 minute to 23 h 59 min |
ALARM INDICATION |
visual, optional audible (buzzer) |
LOGGING INTERVAL |
5 min (standard) |
MEASUREMENT ACCURACY OF THE TIME |
+/- 30 minutes / year |
CALIBRATION |
Every sensor is factory calibrated according NIST/ILAC standard traceable. Calibration certificate on request |
MEMORY SPACE 30 |
30 day overview on display; PDF report length factory settable: 28, 56, 84 or 112 day overview |
BATTERY |
Lithium battery – complies with IATA DGR Packaging Instruction 970-Section II |
PROTECTION CLASS |
IP64 (external sensor not plugged in) |
2D CODE ON LABEL |
2D data matrix |
OPERATING LIFETIME AND SHELF LIFE |
Up to 3 1/2 years (1/2 year storage / 3 years useful life). The battery status indicator on the display provides information on the remaining lifetime. |
WARRANTY |
2 years from date of delivery (see general Berlinger Terms & Conditions) |
MANIPULATION |
Fridge-tag Ultra Low cannot be manipulated, reset or turned off without destroying it |
FORMAT OF THE ORIGINAL DOCUMENT |
PDF / ASCII (it can also be imported by many ERP or data management systems) |
SOFTWARE FOR VERIFYINGPDF AND ASCII FILE |
www.berlinger.com/verifier JAVA™ / The software verifies the digital signature of the ASCII and PDF files. |
STANDARDS |
CE, EMC, ROHS compliant, REACH |
Subject to change. Please note that all information in this document is correct at the time of publication. Due to our policy of continuous product development, we reserve the right to change this information without prior notice. |
Not applicable