Data Loggers, Reference Thermometers
- Logs: 16K
- Range: -100/400°C
- Accuracy: ±0.1°C
- Model: CT376DIG
Home » Products » Reference Thermometers » Explosion Proof Logging Dual Probe – Pt100 Reference Digital Thermometer
Explosion Proof Handheld Reference Thermometers with Dual Probse and Logging ability to record 6,000 measurements.
The resistance thermometer automatically detects the Pt100 smartprobes which have an integrated Eprom where the calibration characteristic of each probe is transferred automatically to the instrument.
Measurements can be easily seen on the large LCD display. The instrument contains numerous functions for the measurement and visualization of readings. Integrated calibration functions, including the intelligent Eprom probes, takes this compact instrument to a high performance class, making it ideally suitable as a primary reference standard.
CATALOG No. | DESCRIPTION |
---|---|
ACCD755LOGEX |
Explosion Proof Logging Dual Probe Reference Digital Thermometer, – Pt100 -200/850°C (-328/1562°F) Accuracy… ±0.02°C -50°C to 200°C / ±0.05°C -200°C to 200°C |
FEATURES:
SPECIFICATIONS:
Input Eprom-probes |
2 Channel, Pt100 (EN60751) |
Measuring Range |
-200°C to +850°C |
Accuracy Pt100 |
±0.02°C from -50°C…+200°C ±0.05°C from -200°C…+200°C 0.1% remaining range |
Resolution: |
0.01°C from -200°C…+200°C otherwise 0.1°C |
Connectors: |
DIN 8-pole |
Display |
2-line LCD |
Data Connector |
USB |
Working Temperature |
0 to +40°C (32 to +104°F) |
Memory |
appr. 6000 measurements (model ACCD755LOG only) |
Measuring Interval |
adjustable: 1 second to 30 minutes (model ACCD755LOG only) |
Housing |
plastic (ABS) |
Dimensions |
8.0” x 3.5” x 1.5” (L-W-H) |
Weight |
0.6 lbs |
Power supply |
1 x 9v battery |
Batterie Life |
appr. 20 hr |
ACCESSORIES:
CATALOG No. | DESCRIPTION |
---|---|
ACCD0081PD |
Windows Software Smartgraph for online documentation |
ACCD0046 |
USB Data Cable |
ACCD0007PD |
Service Case for instrument, probe & accessories, Blue Plastic with inserts |
ACCD10795 |
USB Power Pack |
General Purpose Pt100 Probes, ±0.20°C, 4 Wire platinum – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1001PT |
Immersion w/ handle | 8 sec. | -50 to +350°C | 150 x 3mm |
ACCD1002 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 300 x 3mm |
ACCD1005 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 500 x 3mm |
ACCD1006 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 150 x 4mm |
ACCD1007 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 300 x 4mm |
High Precision Pt100 Probes, ±0.03°C (-30 to +200°C) – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1018 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 150 x 3mm |
ACCD1019 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 3mm |
ACCD1023 |
Immersion w/ handle | 5 sec. | -200 to +450°C | 300 x 1.4mm |
ACCD1078 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 6.0mm |
CALL: (973) 300-9100
9am to 5pm est
Explosion Proof Handheld Reference Thermometers with Dual Probse and Logging ability to record 6,000 measurements.
The resistance thermometer automatically detects the Pt100 smartprobes which have an integrated Eprom where the calibration characteristic of each probe is transferred automatically to the instrument.
Measurements can be easily seen on the large LCD display. The instrument contains numerous functions for the measurement and visualization of readings. Integrated calibration functions, including the intelligent Eprom probes, takes this compact instrument to a high performance class, making it ideally suitable as a primary reference standard.
CATALOG No. | DESCRIPTION |
---|---|
ACCD755LOGEX |
Explosion Proof Logging Dual Probe Reference Digital Thermometer, – Pt100 -200/850°C (-328/1562°F) Accuracy… ±0.02°C -50°C to 200°C / ±0.05°C -200°C to 200°C |
FEATURES:
SPECIFICATIONS:
Input Eprom-probes |
2 Channel, Pt100 (EN60751) |
Measuring Range |
-200°C to +850°C |
Accuracy Pt100 |
±0.02°C from -50°C…+200°C ±0.05°C from -200°C…+200°C 0.1% remaining range |
Resolution: |
0.01°C from -200°C…+200°C otherwise 0.1°C |
Connectors: |
DIN 8-pole |
Display |
2-line LCD |
Data Connector |
USB |
Working Temperature |
0 to +40°C (32 to +104°F) |
Memory |
appr. 6000 measurements (model ACCD755LOG only) |
Measuring Interval |
adjustable: 1 second to 30 minutes (model ACCD755LOG only) |
Housing |
plastic (ABS) |
Dimensions |
8.0” x 3.5” x 1.5” (L-W-H) |
Weight |
0.6 lbs |
Power supply |
1 x 9v battery |
Batterie Life |
appr. 20 hr |
ACCESSORIES:
CATALOG No. | DESCRIPTION |
---|---|
ACCD0081PD |
Windows Software Smartgraph for online documentation |
ACCD0046 |
USB Data Cable |
ACCD0007PD |
Service Case for instrument, probe & accessories, Blue Plastic with inserts |
ACCD10795 |
USB Power Pack |
General Purpose Pt100 Probes, ±0.20°C, 4 Wire platinum – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1001PT |
Immersion w/ handle | 8 sec. | -50 to +350°C | 150 x 3mm |
ACCD1002 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 300 x 3mm |
ACCD1005 |
Immersion w/ handle | 8 sec. | -50 to +350°C | 500 x 3mm |
ACCD1006 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 150 x 4mm |
ACCD1007 |
Insertion w/ handle | 10 sec. | -50 to +350°C | 300 x 4mm |
High Precision Pt100 Probes, ±0.03°C (-30 to +200°C) – 1 Meter Cable PVC
CATALOG NO. | Probe Type | T90 Response Time | Measuring Range | Length x Dia. |
---|---|---|---|---|
ACCD1018 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 150 x 3mm |
ACCD1019 |
Immersion w/ handle | 12 sec. | -200 to +450°C | 300 x 3mm |
ACCD1023 |
Immersion w/ handle | 5 sec. | -200 to +450°C | 300 x 1.4mm |
ACCD1078 |